Walk in Stability Chamber in Pharmaceutical

Model: YWER-41000

Main Parameters:


Temperature range: 20℃~80℃

Humidity range: 50-75%RH


Get Walk in Stability Chamber in Pharmaceutical Price
Description Parameters Features

Description of Walk in Stability Chamber in Pharmaceutical

Walk in stability test chamber is used to test the law of changes in raw materials or pharmaceutical preparations over time under the influence of specific temperature and humidity, to provide scientific basis for the production, packaging, storage, and transportation conditions of drugs, and to establish the validity period of drugs through experiments.

Drug stability tests include influencing factor tests, accelerated tests and long-term tests.

1. Factor tests:High temperature test (not exceeding 60C) and high humidity test (usually not exceeding 75%)

2. Accelerated tests:The samples are divided into three batches, which are observed for 6 months in the environment of 40℃±2℃/75%RH±5%RH and 25℃±2℃/60%RH±5%RH respectively, at 30℃ ±2℃/65%RH±5%RH Observe for 12 months in an environment .

3. Long-term tests: Observe in the environment of 25℃±2℃/60%RH±5%RH and 30℃±2℃/65%RH±5%RH for more than 12 months.


Effects of Low Humidity

Static buildup is a major effect of relative humidity levels dropping below 45 percent. The accumulation of static charges can dry out medications, affecting the intended behavior of any solvents used in production. The excess static can also cause products to dry out and crumble, or stick together, leading to problems during tablet pressing and packaging.


Effects of High Humidity

High humidity causes products to absorb the excess moisture in the air, which can be just as destructive as environments with low humidity. Too much humidity can compromise potency and effectiveness, leading to degradation or even toxicity in some products. The potential for danger comes when relative humidity levels reach 60 percent or more; giving viruses, bacteria, mold, fungi and mites the opportunity to grow.


Parameter of Walk in stability chamber in pharmaceutical


Model

YWER-41000

Chamber SizeNon-standard
Temperature range

20℃~80℃

Humidity range50-75%RH
Temp.Humi fluctuation±0.3℃;±0.5%RH
Temp.Humi uniformity±3℃;±5%RH
Indication ResolutionTemperature:0.01 humidity:0.1%RH
Heat-up and  Cool-down timeHeat-up:2℃/min(Average),cool-down time 1℃/min(Average)
Air circulation systemCentrifugal fan air circulation system
Heating systemSUS#Stainless steel high-speed heater
Humidification systemElectrothermal steam humidification
Refrigeration systemCompressor + Finned evaporator + Air(Water) cooled condenser
Dehumidifying systemdew point dehumidification method
Controlling systemTouch screen controller+SSR+PID
Exterior chamber materialCold-rolled plate + Powder coating
Interior chamber materialSUS#304 Stainless steel
Insulation materialPU +fibergalss wool
componentsVacuum glass observation window
Test hole (50mm)
Control status indicator
Interior light
Overheat protection circuit breaker
Safety protection deviceHumidification system overheat protection
Compressor overload protection
Control system overload protection
Overload indicator
Phase sequence protection
Water shortage protection
High voltage and low voltage protection
Over-temperature protection
Water supply delay protection
Fan overcurrent protection
Power supplyAC 3Ψ380V 60/50Hz Power supply can be customized
Customization serviceNon-standard or special requirements are all welcome





Features of Walk in Stability Chamber in Pharmaceutical

1. Programmable LCD touch screen temperature controller, support multiple languages.

2. Automatic replenishment function.

3. Access to PC remote control and monitoring.

4. Air cooling.

5. Custom service.

6. Door with a large view window, able to observe the test status of the test product.


Related Walk In Chamber for Sale